cooler for pressured water
project data:
2 parallel 40 bar-bundles with removable header covers; EN13445.
year:2019location:Ludwigshafen, DEbranch:chemical industryuse:cooler for pressured watertube side:watermaterial:A316Ti (1.4571)type of tubes:E-Finperformance (kW):2000 kW -
cooler for pressured water
project data:
2 parallel bundles for cooling of pressured water; induced draught fans.
year:2007location:Brunsbüttel, DEbranch:chemical industryuse:cooler for pressured watertube side:watermaterial:A321 (1.4541)type of tubes:W-Finperformance (kW):1003 kW -
condenser
project data:air-cooled condenser for vapours; removable header covers.
year:2007location:Hamburg, DEbranch:petro-chemical industryuse:condensertube side:vapoursmaterial:carbon steeltype of tubes:E-Finperformance (kW):2570 kW -
visco-cooler
project data:cooler for high-viscous oil residue; removable header covers.
year:2011location:Hamburg, DEbranch:petro-chemical industryuse:visco-coolertube side:high viscous oilsmaterial:carbon steeltype of tubes:E-Finperformance (kW):512 kW -
water cooler
project data:cooler for polluted process water; with removable header covers.
year:2014location:Marl, DEbranch:chemical industryuse:water coolertube side:watermaterial:A316Ti (1.4571)type of tubes:E-Finperformance (kW):615 kW -
water-glycol cooler
project data:cooler for water-glycol; with removable header covers.
year:2010location:Hamburg, DEbranch:petro-chemical industryuse:water-glycol coolertube side:water-glycolmaterial:carbon steeltype of tubes:E-Finperformance (kW):2050 kW -
visco-cooler
project data:cooler for high-viscous oil residue; removable header covers.
year:2011location:Hamburg, DEbranch:petro-chemical industryuse:visco-coolertube side:high viscous oilsmaterial:carbon steeltype of tubes:E-Finperformance (kW):512 kW -
water-glycol cooler
project data:3 cooling systems for water; completely with pump skids and vessels.
year:2010location:Hamburg, DEbranch:petro-chemical industryuse:water-glycol coolertube side:water-glycolmaterial:carbon steeltype of tubes:E-Finperformance (kW):153 kW -
visco-cooler
project data:5 parallel coolers with integrated pre-heaters for high-viscous oils.
year:2005location:Salzbergen, DEbranch:petro-chemical industryuse:visco-coolertube side:high viscous oilsmaterial:carbon steeltype of tubes:E-Finperformance (kW):1138 kW -
water-glycol cooler
project data:cooler for water-glycol; with removable header covers; total length 13.5 m.
year:2010location:Hamburg, DEbranch:petro-chemical industryuse:water-glycol coolertube side:water-glycolmaterial:carbon steeltype of tubes:E-Finperformance (kW):2050 kW -
condenser
project data:2 parallel condensers for vapours.
year:2008location:Antwerpen, BEbranch:chemical industryuse:condensertube side:vapoursmaterial:A321 (1.4541)type of tubes:W-Finperformance (kW):3500 kW -
shut-down cooler
project data:1-pass shut-down cooler.
year:2003location:Orla, DEbranch:wood industryuse:shut-down coolertube side:thermal oilmaterial:carbon steeltype of tubes:E-Finperformance (kW):3000 kW -
shut-down cooler
project data:1-pass shut-down cooler.
year:2007location:Bischweyer, FRbranch:wood industryuse:shut-down coolertube side:thermal oilmaterial:carbon steeltype of tubes:E-Finperformance (kW):6812 kW -
condenser
project data:2 tripartite air-cooled condenser for vapours; removable header covers.
year:2007location:Hamburg, DEbranch:petro-chemical industryuse:condensertube side:vapoursmaterial:A316Ti (1.4571)type of tubes:E-Finperformance (kW):6800 kW -
shut-down cooler
project data:1-pass shut-down cooler.
year:2009location:Brasov, RObranch:wood industryuse:shut-down coolertube side:thermal oilmaterial:carbon steeltype of tubes:E-Finperformance (kW):7462 kW -
shut-down cooler
project data:1-pass shut-down cooler.
year:2011location:Riga, LVbranch:wood industryuse:shut-down coolertube side:thermal oilmaterial:carbon steeltype of tubes:E-Finperformance (kW):3001 kW -
process cooler
project data:cooler in hanging installation.
year:2013location:Dresden, DEbranch:wood industryuse:process coolertube side:condensatematerial:carbon steeltype of tubes:E-Finperformance (kW):672 kW -
condenser
project data:2 tripartite air-cooled condensers for vapours; steel support.
year:2007 (erection)location:Hamburg, DEbranch:petro-chemical industryuse:condensertube side:vapoursmaterial:A316Ti (1.4571)type of tubes:E-Finperformance (kW):6800 kW -
condenser
project data:2 tripartite air-cooled condensers for vapours; axial fans.
year:2007(erection)location:Hamburg, DEbranch:petro-chemical industryuse:condensertube side:vapoursmaterial:A316Ti (1.4571)type of tubes:E-Finperformance (kW):6800 kW -
condenser
project data:2 tripartite air-cooled condensers for vapours; steel support.
year:2007 (erection)location:Hamburg, DEbranch:petro-chemical industryuse:condensertube side:vapoursmaterial:A316Ti (1.4571)type of tubes:E-Finperformance (kW):6800 kW -
condenser
project data:2 tripartite air-cooled condensers for vapours; assembling of bundles.
year:2007 (erection)location:Hamburg, DEbranch:petro-chemical industryuse:condensertube side:vapoursmaterial:A316Ti (1.4571)type of tubes:E-Finperformance (kW):6800 kW -
condenser
project data:2 tripartite air-cooled condensers for vapours; assembling of bundles.
year:2007 (erection)location:Hamburg, DEbranch:petro-chemical industryuse:condensertube side:vapoursmaterial:A316Ti (1.4571)type of tubes:E-Finperformance (kW):6800 kW
Air-Cooled Systems
WE DESIGN YOUR HEAT EXCHANGERS/AIR-COOLED PLANTS AND SYSTEMS
As a reliable and quality-oriented partner, we help you stay on top of the constant challenges in the development of heat transfer systems.
We are also happy to discuss with you your projects, ideas and individual needs in the area of heat transfer.